Double Wall Reactors ATR ASAHI Process System (P) Ltd -

Double Wall Glass Reactor With Ring Baffle And Without Ring Baffle

Double Wall Glass Reactor With Ring Baffle And Without Ring Baffle

Glass Reactors

The Glass reactors as they are referred to are made of solid glass which makes them convenient to be seen from outside for reaction taking place inside. The Glass reactors can be of single jacket (Double wall) or double jacket (triple wall) reactors. The Glass reactors are identified at the bench top/lab scale, kilo and pilot scale.

Bench-top Reactor (ASAHI GLASSPLANT INC. AG! Make)
Vessel Capacity 300mL,500mL,1L,2L,3L,5L
Vessel type Double Wall; Jacketed and Triple Wall
Operating Pressure (-)1 bar g (full vacuum) to (+) 0.5 bar g (+0.05MPa)
Operating Temperature (-) 90 deg c to (+) 230 deg c
Delta T 60 deg c(Triple Wall) , 110 deg c(Double wall; Jacketed)
All reactors use the same cover and height adjustable stand
The system additionally requires overhead stirrer and heating cooling machine
Reaction unit laboratory model (ASAHI GLASSPLANT INC. AG! Make)
Vessel Capacity 300mL,500mL,1L,2L,3L,6L
Vessel type Double Wall; Jacketed, Fully Jacketed  Triple Wall
Operating Pressure (-)1 bar g (full vacuum) to (+) 0.5 bar g (+0.05MPa)
Operating Temperature (-) 130 deg c to (+) 250 deg c
Delta T 60 deg c(Triple Wall) , 110 deg c(Double wall; Jacketed, fully jacketed)
Reaction unit Plant model (ASAHI GLASSPLANT INC. AG! Make)
Vessel Capacity 10 to 100 L (Triple Wall), DN500 (max)

10 to 300L (Double Wall, Jacketed), DN600 (max)

Vessel type Double Wall; Jacketed, Triple Wall
Operating Pressure (-)1 bar g (full vacuum) to (+) 0.5 bar g (+0.05MPa)
Operating Temperature (-) 130 deg c to (+) 250 deg c
Delta T 60 deg c(Triple Wall) , 110 deg c(Double wall; Jacketed)
Pilot-plant Reactor Fully functional Stand (ASAHI GLASSPLANT INC. AG! Make)
Vessel Capacity 10L,20L,30L
Vessel type Double Wall; Jacketed, Triple Wall
Operating Pressure (-)1 bar g (full vacuum) to (+) 0.5 bar g (+0.05MPa)
Operating Temperature (-) 90 deg c to (+) 230 deg c
Delta T 60 deg c(Triple Wall) , 110 deg c(Double wall; Jacketed)
The system will require to include overhead stirrer and thermostat
Pilot-plant Reactor Stationary Stand (ASAHI GLASSPLANT INC. AG! Make)
Vessel Capacity 10L,20L,30L,50L,100L (Double Wall, Jacketed),10,20,30,60L (Triple Wall)
Vessel type Double Wall; Jacketed, Triple Wall
Operating Pressure (-)1 bar g (full vacuum) to (+) 0.5 bar g (+0.05MPa)
Operating Temperature (-) 90 deg c to (+) 230 deg c
Delta T 60 deg c(Triple Wall) , 110 deg c(Double wall; Jacketed)
The system will require to include overhead stirrer and thermostat

Special Features

Minimum Dead Space At Bottom

All reactors are designed without dead space to ensure complete drainage.
They are equipped with cocks spring loaded to guarantee a leak free seal over the entire temperature range at all times. The design complies with GMP standards.

Variety of Vessel Options

Triple Wall with Ring Baffle, Triple Wall, Double Wall with ring baffle, Double Wall. From 10L to 100L (Triple wall with ring baffles), 100L (Double wall with ring baffles), 300L (Double wall, custom made).

Accurate Temperature Control

Glass ring baffles distribute heat transfer fluid evenly throughout the jacket, promising precise temperature control and allowing temperature control units to operate at maximum efficiency with fast heating/cooling response.

Double Wall Glass Reactor With Ring Baffle And Without Ring Baffle

  • Double Wall Glass Reactor
  • Double Wall Glass Reactor2
  • Double Wall Glass Reactor3
  • Double Wall Glass Reactor4
  • Double Wall Glass Reactor5
  • Double Wall Glass Reactor6
  • Double Wall Glass Reactor7
  • Double Wall Glass Reactor8
  • Double Wall Glass Reactor9
  • Double Wall Glass Reactor10
  • Double Wall Glass Reactor11
  • Glass Reactor12
  • Glass Reactors

Product Video